- Hand-Fired Coal, Wood, Oil Boiler
- 90/105 Stoker
- Baywindow
- Econo90
- Econo60
- Hand-Fired Fireplace Insert 70/90
- Hand-Fired Hopper 70/90
- Hand-Fired 70/90
- Hearth
- Warm Air Furnace
- Koker Furnace
- Koker Light
- Boilers

- Insulated Steel Jacket, Cast Iron Fire Door and Grate
- Temperature/Altitude Gauge
- Domestic Hot Water Coil
- 3/4″ Pressure Relief Valve
- Large Ash pan
- Optional Oil Burner: Beckett burner Gun
- Several boiler Tappings for your convenience:
- Top: A 2″ and a 3/4″ Tap; 2-1/2″ Taps
- Stack End: 2-2″ Taps
*This boiler is NOT UL listed or ASME certified for installation in NJ Homes or Businesses.
Specifications | 140 | 180 |
---|---|---|
BTU’s (Nut Anthracite) | 140,000 | 180,000 |
Burns wood logs up to: | 18″ | |
Flue Size | 8″ | |
Height | 45″ | |
Width | 25″ | |
Depth | 28″ | 33″ |
Weight | 600 lbs. | 650 lbs. |
Water Capacity | 24 Gallons | 33 Gallons |
Firebox/Grate Area | 14″L x 18″W x 11″H | 19″L x 18″W x 11″H |

Specifications | 90 Single Wall | 105 Double Wall |
---|---|---|
BTU’s | 90,000 | 105,000 |
Flue Exit | Top/Rear | Top/Rear |
Flue Size | 6″ | 6″ |
Rear Flue Height | 6″ | 6″ |
Height | 39″ | 39″ |
Width | 23 ½” | 23 ½” |
Depth | 35″ | 35″ |
Weight | 305 lbs | 355 lbs |
Hopper Capacity | 110 lb | 110 lb |
Blower CFM | 265 | 350 |
Glass Door | Yes | Yes |
Rear Clearance | 0″ | 0″ |
Side Clearance | 8″ | 8″ |

Specifications | |
---|---|
BTU’s | 75,000 |
Flue Exit | Top/Rear |
Flue Size | 6″ |
Rear Flue Height | 1″ |
Height | 28″ |
Width | 25″ |
Depth | 31 ½” |
Weight | 243 lbs |
Hopper Capacity | 80 lbs |
Blower CFM | 265 CFM |
Glass Door | Yes |
Rear Clearance | 4″ |
Side Clearance | 12″ |

Width | Depth | Height | |
---|---|---|---|
Unit | 23″ | 35″ with hopper | 38″ |
Door Opening | 15 1/4″ | — | 10″ |
Glass | None | — | — |
Flu Size | 6″ Top or Rear Vent | Plenum Opening: | 14″x8″ |
Weight | 315 lbs. | ||
Hopper Capacity | 100 lbs. Stainless Steel | ||
Blower | 500 CFM No Filter Box | ||
Optional SS HW Coil | |||
BTU Output | 90,000 | 2,200 sq. ft. capacity max |

Width | Depth | Height | |
---|---|---|---|
Unit | 23″ | 35″ with hopper | 38″ |
Door Opening | 15 1/4″ | — | 10″ |
Glass | None | — | — |
Flu Size | 6″ Top or Rear Vent | Plenum Opening: | 14″x8″ |
Weight | 315 lbs. | ||
Hopper Capacity | 80 lbs. Stainless Steel | ||
Blower | No Filter Box | ||
BTU Output | 60,000 | 1,800 sq. ft. capacity max |

Radiant Stove Specifications | HF70 | HF90 |
---|---|---|
BTU’s | 70,000 | 90,000 |
Flue Exit | Top | Top |
Flue Size | 6″ | 6″ |
Rear Flue Height | 23 ½” | 23 ½” |
Height | *I 23 ½” | *I 23 ½” |
*O 32″ | *O 32″ | |
Width | *I 21″ | *I 21″ |
*O 46″ | *O 46″ | |
Depth | *I 13″ | *I 16″ |
*O 7″ | *O 8″ | |
Weight | 400 lbs | 425 lbs |
Glass Door | Yes | Yes |
Optional Blower CFM | 220 | 220 |
Rear Clearance | — | — |
Side Clearance | 16″ | 16″ |
*I – Stove dimension inside the hearth *O Stove dimension outside the hearth

Radiant Stove Specifications | H.F Hopper |
---|---|
BTU’s | 90,000 |
Flue Exit | Rear |
Flue Size | 6″ |
Rear Flue Height | 23″ |
Height | 34″ |
Width | 25 ½” |
Depth | 21″ |
Weight | 370 |
Glass Door | Yes |
Optional Blower CFM | 45 |
Rear Clearance | 12″ |
Side Clearance | 12″ |

1. Result in most complete burning of coal 2. Extract maximum amount of heat from coal 3. Enable an attractive small parlor stove to heat a large area
- Burns Pea or Nut Coal
- Comes standard with 265 CFM blower
- Optional brass trim fire door
- Available in top and rear exhaust
- A 220 CFM blower option available
Specifications | HF70 | HF90 |
---|---|---|
BTU’s | 70,000 | 90,000 |
Flue Exit | Top/Rear | Top/Rear |
Flue Size | 6″ | 6″ |
Rear Flue Height | 26″ | 26″ |
Height | 34.5″ | 34.5″ |
Width | 23″ | 23″ |
Depth | 19″ | 19″ |
Weight | 460 lbs. | 560 lbs. |
Glass Door | Yes | Yes |
Blower Size | 265 | 265 |
Rear Clearance | 16″ | 16″ |
Side Clearance | 12″ | 12″ |

Specifications | Hearth |
---|---|
BTU’s | 90,000 |
Flue Exit | Rear |
Flue Size | 6″ |
Rear Flue Height | 3.5″ |
Height | 34″ |
Width | 44″ |
Depth | 18″ |
Weight | 350 lbs |
Hopper Capacity | 50 lbs |
Blower CFM | 265 CFM |
Glass door | Yes |
Rear Clearance | 0″ |
Side Clearance | 12″ |

The downdraft heat exchanger increases heating surface, permitting circulation of every thermal unit of heat into the warm air lender pipes for rapid distribution.
Sealed ash pit assures clean dust-free operation.
Five Sizes Available: 25,000 150,000 250,000 350,000 450,000
Standard equipment includes: three controls, room thermostat timer, relay control, blower and motor.
Model No. | B.T.U. | Length | Height | Width |
---|---|---|---|---|
A-80 | 125,000 | 66″ | 48″ | 27″ |
A-150 | 150,000 | 78″ | 48″ | 30″ |
A-250 | 250,000 | 88″ | 54.5″ | 36 3/4″ |
A-350 | 350,000 | 94″ | 60″ | 41″ |
A-450 | 450,000 | 94″ | 66″ | 41″ |
Dimen. | A-80 | A-150 | A-250 | A-350 | A-450 |
---|---|---|---|---|---|
A | 20″ | 24″ | 30″ | 30″ | 30″ |
B | 66″ | 78.5″ | 86.6″ | 91.75″ | 92″ |
C | 20×20″ | 24 x 24″ | 23×30 | 25″ x 32″ | 24″ x 40″ |
D | 20 1/4″ x 22 1/4″ | 24 3/8″ x 26 1/4″ | 28 1/2″ x 28 1/2″ | 28″ x 28″ | 34 3/4″ x 36 1/2″ |
E | 48″ | 56″ | 65″ | 70.5″ | 71″ |
F | 26.5″ | 30.5″ | 36.6″ | 40.5″ | 41″ |
G | 48″ | 48″ | 54.5″ | 60″ | 66″ |
H | 15.5″ | 32.5″ | 39″ | 38″ | — |
Stack | 8″ | 9″ | 10″ | 10″ | 10″ |

Tested at 88 to 90% Efficiency
The Koker can be chimney vented or direct vented. It is completely automatic, working off a Honeywell Room Thermostat. Optional stainless steel water coil available.
Specifications | |
---|---|
BTU’s | 160,000 |
Flue Exit | Top/Rear |
Flue Size | 6″ |
Rear Flue Height | 5″ |
Height | 49″ |
Width | 26″ |
Depth | 49″ |
Weight | 550 lbs |
Hopper Capacity | 240 lbs |
Blower CFM | 1,500 CFM |
Glass Door | Yes |
Rear Clearance | 18″ |
Side Clearance | 18″ |

Width | Depth | Height | |
---|---|---|---|
Unit | 26″ | 24 3/4″ | 44″ |
Door Opening | 15 1/4″ | — | 9″ |
Glass | None | — | 7″ |
Flu Size | 6″ Top or Rear Vent | Plenum Opening: | 14″x8″ |
Weight | 400 lbs. | ||
Hopper Capacity | 200 lbs. Stainless Steel | ||
Blower | 1000 CFM Air Filter Box | ||
Extra Large Ashpan | |||
BTU Output | 105,000 | 2,500 sq. ft. capacity |

- Stoker
- Jacket
- Hopper
- 5 Gallon Coil
- Auto Damper
- Altitude Gauge
- Timer
- Thermostat
- Triple Aquastat
- 4006B Aquastat
- (pressurized) Relief Valve
- 2 Ash Buckets
- B30 Secondary Combustion Blower
Closed System: Circulator is needed
NOTE: Boilers so noted are now ASME certified and priced accordingly
Model No. | Total Capacity per Square Feet of Radiation | Recommended Load Square Feet of Radiation | B.T.U. per HR to the Nearast Thousand | Hopper Capacity lbs | ASME Certified | |||
---|---|---|---|---|---|---|---|---|
Steam | Hot W. | Steam | Hot W. | Net | Gross | |||
KAA-2 | — | 480 | — | 400 | 76 | 90 | 100 | Not Yet |
KA-4 | — | 720 | — | 537 | 102 | 120 | 200 | Certified |
KA-6 | 600 | 960 | 420 | 675 | 122 | 144 | 275 | Certified |
KB-8 | 800 | 1,280 | 560 | 900 | 163 | 192 | 315 | Certified |
KC-10 | 1,000 | 1,600 | 700 | 1,125 | 204 | 240 | 450 | No |
KD-12 | 1,200 | 1,920 | 840 | 1,350 | 245 | 288 | 525 | Certified |
KE-15 | 1,500 | 2,400 | 1,050 | 1,690 | 306 | 360 | 525 | Certified |
KF-18 | 1,800 | 2,880 | 1,260 | 2,025 | 367 | 432 | 525 | No |
KG-22 | 2,200 | 3,520 | 1,540 | 2,475 | 448 | 528 | 585 | Certified |
*I – Stove dimension inside the hearth *O Stove dimension outside the hearth
Model | # of Grates 3″x14″ | Gallons of Water | Smoke Outlet Size | Width | Length | Height |
---|---|---|---|---|---|---|
AA-K2 | 1 | 24 | 6″ | 22.5″ | 27.5″ | 36″ |
AA-K4 | 3 | 34 | 6″ | 22″ | 34″ | 47″ |
A | 3 | 55 | 8″ | 24″ | 40″ | 52.5″ |
B | 4 | 74 | 9″ | 29″ | 42″ | 55″ |
C | 5 | 86 | 10″ | 31″ | 44″ | 56″ |
D | 6 | 96 | 10″ | 31″ | 50″ | 55″ |
E | 7 | 122 | 12″ | 33″ | 55″ | 57″ |
F | 8 | 154 | 12″ | 33″ | 54.5″ | 61″ |
G | 9 | 188 | 14″ | 37″ | 62.5″ | 61″ |